Significance The stratum corneum (SC) is crucial for maintaining skin barrier integrity, a function that is compromised in chronic conditions in such as atopic dermatitis (AD). Although AD pathophysiology involves deeper skin layers, the SC also exhibits significant structural and functional alterations.
Is this you? As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.
Claim your profile
Articles by Daniel Topgaard
In vivo rat brain mapping of multiple gray matter water populations using nonparametric D(ω)‐R1‐R2 distributions MRI
τE echo time τR repetition time ω diffusion frequency b diffusion encoding tensor bΔ encoding anisotropy b(ω) diffusion encoding spectrum Cb cerebellum CBGr cerebellar granule cell layer CBML cerebellar molecular layer cc corpus callosum cg cingulum CSF cerebrospinal fluid D diffusion tensor DΔ(ω) frequency-dependent normalized diffusion anisotropy Diso(ω) frequency-dependent isotropic diffusivity DTD diffusion tensor distribution ECIC external cortex of the inferior colliculus FLASH fast...
In vivo rat-brain mapping of multiple gray matter water populations using nonparametric D(omega)-R1-R2 distributions MRI
Abstract Massively Multidimensional Diffusion MRI combines tensor-valued encoding, oscillating gradients, and diffusion-relaxation correlation to provide multicomponent sub-voxel parameters depicting the tissue microstructure. This method was successfully implemented ex vivo in micro-imaging systems and in clinical conditions but with a reduced diffusion frequency (omega) range due to the use of classical tensor-valued encoding.
Accuracy and precision of statistical descriptors obtained from multidimensional diffusion signal inversion algorithms
Abstract In biological tissues, typical MRI voxels comprise multiple microscopic environments, the local organization of which can be captured by microscopic diffusion tensors. The measured diffusion MRI signal can, therefore, be written as the multidimensional Laplace transform of an intravoxel diffusion tensor distribution (DTD).
Diffusion tensor distribution imaging of an in vivo mouse brain at ultrahigh magnetic field by spatiotemporal encoding
Abstract Diffusion tensor distribution (DTD) imaging builds on principles from diffusion, solid‐state and low‐field NMR spectroscopies, to quantify the contents of heterogeneous voxels as nonparametric distributions, with tensor “size”, “shape” and orientation having direct relations to corresponding microstructural properties of biological tissues.
Diffusion tensor distribution imaging of an in vivo mouse brain at ultrahigh magnetic field by spatiotemporal encoding
Abstract Diffusion tensor distribution (DTD) imaging builds on principles from diffusion, solid‐state and low‐field NMR spectroscopies, to quantify the contents of heterogeneous voxels as nonparametric distributions, with tensor “size”, “shape” and orientation having direct relations to corresponding microstructural properties of biological tissues.
Accuracy and precision of statistical descriptors obtained from multidimensional diffusion signal inversion algorithms
Abstract In biological tissues, typical MRI voxels comprise multiple microscopic environments, the local organization of which can be captured by microscopic diffusion tensors. The measured diffusion MRI signal can, therefore, be written as the multidimensional Laplace transform of an intravoxel diffusion tensor distribution (DTD).
Lipid Dynamics and Phase Transition within α-Synuclein Amyloid Fibrils
Download Hi-Res ImageDownload to MS-PowerPointCite This:J. Phys. Chem. Lett. 2019, 10, 24 RETURN TO ISSUEPREVLetterNEXT Céline Galvagnion* Céline Galvagnion Centre for Misfolding Diseases, Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW, United Kingdom German Center for Neurodegenerative Diseases, Sigmund-Freud-Str. 27, 53127 Bonn,Germany *E-mail: .
Diffusion tensor distribution imaging
Abstract Conventional diffusion MRI yields voxel‐averaged parameters that suffer from ambiguities for heterogeneous anisotropic materials such as brain tissue.
Resolution limit of cylinder diameter estimation by diffusion MRI: The impact of gradient waveform and orientation dispersion
Diffusion MRI has been proposed as a non-invasive technique for axonal diameter mapping. However, accurate estimation of small diameters requires strong gradients, which is a challenge for the transition of the technique from preclinical to clinical MRI scanners, since these have weaker gradients. In this work, we develop a framework to estimate the lower bound for accurate diameter estimation, which we refer to as the resolution limit.
Show More
loading
Actions
Is this you?
As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.Get in touch with Daniel
Contact Daniel, search articles and posts on X, monitor coverage, and track replies from one place.
Learn more about Muck Rack