Category Equipment Surgical: carotid exposure Scalpel (N°15), self-retaining retractor (Weitlaner type), Metzenbaum scissors (fine, curved), DeBakey forceps (atraumatic), right-angle dissector, vessel loops for CCA retraction and vagus nerve protection (× 3), electrocautery, headlight Vascular control: purse-string technique Polypropylene 5-0/6-0 (non-absorbable, double-armed) for two continuous purse-string sutures, tourniquet snares (x 2), atraumatic vascular clamps (x 2, 6-10 mm) on...
Is this you? As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.
Claim your profile
Articles by Thomas Modine
Transcatheter mitral valve replacement in 2026: expanding frontiers in transcatheter mitral therapy
Participate in this live event Register with your My PCR account, add it to your calendar and receive automatic reminders.
EuroPCR 25: The TRICURE EU Study: TRiCares Topaz Transfemoral Tricuspid Valve Replacement System
EuroPCR 25 - First-in-human outcomes from the TRiCares Topaz Tricuspid Valve Replacement System in patents with tricuspid regurgitation (TR) show positive performance results and improved safety.
EuroPCR 25: BIOADAPTOR RCT 3Y Outcomes
Skip to main content Video Published: Views: 9 Likes: 0 Average (ratings) EuroPCR25 - Novel DynamX Bioadaptor demonstrates a sustained reduction of device-related events from six-month to three-year follow-up compared to drug-eluting stents (DES). We are joined by Dr Shigeru Saito (Shonan Kamakura General Hospital, Kamakura, JP) to discuss key findings from the BIOADAPTOR RCT trial (NCT04192747).
EuroPCR 25: LANDMARK: 1Y Outcomes of Myval THV in Patients with Aortic Stenosis
EuroPCR 25 - Novel Myval THV shows non-inferiority at one year compared to established valves in severe aortic stenosis. We are joined by Dr Patrick Serruys (Erasmus University Medical Center, Rotterdam, NL) to discuss key findings from the LANDMARK trial.
EuroPCR 25: TRINITY: 30 Day Outcomes of LuX-Valve TAVR System
Video Published: Views: 7 Likes: 0 Average (ratings) EuroPCR25 - Findings from TRINITY show favourable outcomes with the LuX-Valve Plus TTVR system in high-risk patients with severe tricuspid regurgitation. We are joined by Prof Thomas Modine (Lille University Hospital, Lille, FR) to discuss key findings from the TRINITY trial.
EuroPCR 25: Optical Coherence Tomography-Guided PCI in Acute Coronary Syndrome Patients
EuroPCR 25 - Subgroup analysis outcomes from OCCUPI show optical coherence tomography-guided percutaneous coronary intervention (PCI) is an effective intravascular imaging technique for complex lesions, having successfully met its composite primary outcome measure.
TCT Middle East 25: Minimally Invasive Surgery
Video Published: Views: 44 Likes: 0 Average (ratings) TCT Middle East 2025 — We are joined by Prof Rania Hammami and Dr Uthman Aluthman as they discuss the key takeaways for minimally invasive surgery from the conference. The specialists provide insights on evolving definitions and expanding applications of minimally invasive cardiac surgical techniques. They address practical considerations regarding patient selection, recovery trajectories, and institutional implementation.
Transcarotid Access for TAVR
Transcatheter aortic valve replacement (TAVR) has revolutionized the management of severe aortic stenosis. As TAVR techniques continue to evolve, optimizing the access route plays a crucial role in procedural success and patient outcomes. Traditionally, transfemoral (TF) access has been the primary access route for TAVR.
Anatomic suitability for transapical transcatheter mitral valve implantation using a tether‐based device
Identification of CT variables For the purpose of this investigation, specific measurements were selected among those collected for the main clinical trial. Selection was based on the principle that these measurements were independent of comprehensive segmentation of the mitral annulus and could potentially be performed using simple multi-planar reformats as opposed to dedicated postprocessing platforms.
How to Do It: Preventing LVOT Obstruction Valve-in-Valve TMVR
This article is part of CTSNet’s Guest Editor Series, 21 Years After First TAVI: Will Pace of Innovations Continue for All Heart Valves? Guest editor Gry Dahle has curated a robust collection of content that shares the knowledge, techniques, and insights of several distinguished experts from around the world.
Transapical TMVI: Tendyne Valve
This article is part of CTSNet’s Guest Editor Series, 21 Years After First TAVI: Will Pace of Innovations Continue for All Heart Valves? Guest editor Gry Dahle has curated a robust collection of content that shares the knowledge, techniques, and insights of several distinguished experts from around the world.
Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement: How to Prevent It?
Introduction Transcatheter mitral valve replacement (TMVR) has emerged as an alternative to surgical mitral valve replacement (SMVR) for the treatment of mitral valve disease.1 Among its possible complications, left ventricular outflow tract (LVOT) obstruction can be a life-threatening situation and is associated with procedural morbidity and mortality. The incidence of LVOT obstruction during TVMR is relatively low.
Advances in transcatheter mitral and tricuspid therapies
Abstract Background While rheumatic mitral stenosis has been effectively treated percutaneously for more than 20 years, mitral and tricuspid regurgitation treatment appear as a contemporary unmet need. The advent of transcatheter therapies offer new treatment options to often elderly and frail patients at high risk for open surgery. We aimed at providing an updated review of fast-growing domain of transcatheter mitral and tricuspid technology.
Cardiac Interventions Today - Imaging Considerations in PCI and Update on Mitral and Tricuspid Valve Interventions
Evidence for the benefit of intraprocedural intravascular ultrasound (IVUS) in percutaneous coronary intervention (PCI) continues to mount. Another randomized controlled trial, in a near all-comer population, builds on previous observational and randomized trial data, highlighting the benefit of this technology. In this issue of Cardiac Interventions Today, we expand imaging beyond IVUS and explore novel up-and-coming technologies that are likely to make a significant impact in clinical practice.
Alternate Access for TAVI: Stay Clear of the Chest
Login or register to view PDF. Abstract Transcatheter aortic valve implantation (TAVI) is currently performed through an alternative access in 15 % of patients. The transapical access is progressively being abandoned as a result of its invasiveness and poor outcomes. Existing data does not allow TAVI operators to favour one access over another — between transcarotid, trans-subclavian and transaortic — because all have specific strengths and weaknesses.
FFR-Guided Complete Revascularization Evaluated in Patients With STEMI and Severe Nonculprit Disease
April 17, 2017—A substudy of the DANAMI-3–PRIMULTI trial demonstrated that fractional flow reserve (FFR)-guided complete revascularization improves the prognosis in patients with ST-segment elevation myocardial infarction (STEMI) and severe nonculprit disease. The findings were published online ahead of print by Jacob Lønborg, MD, et al in Circulation: Cardiovascular Interventions.
Choice of Stent Evaluated for PCI of Saphenous Vein Grafts
April 17, 2017—An evaluation of the choice of stent for percutaneous coronary intervention (PCI) of saphenous vein grafts (SVGs) was published by Javaid Iqbal, MD, et al in Circulation: Cardiovascular Interventions. The investigators aimed to assess clinical outcomes after PCI of SVGs in patients receiving bare-metal stents (BMSs), first-generation drug-eluting stents (DESs), and newer-generation DESs in a large unselected national data set from the British Cardiovascular Intervention Society.
New Insights From the STS/ACC TVT Registry
After the approval of the first transcatheter aortic valve prostheses by the US Food and Drug Administration (FDA) in November 2011, a National Coverage Decision (NCD) for transcatheter aortic valve replacement (TAVR) was developed by the Centers for Medicare & Medicaid Services (CMS).
Echocardiographic Aortic Annulus Sizing for TAVR
Aortic annulus anatomy has become a crucial component of preprocedural planning in transcatheter aortic valve replacement (TAVR) procedures.1 Annulus sizing is essential to procedural success and to avoid complications such as perivalvular regurgitation, annular disruption, valve embolization, and coronary occlusion.2-4 There is increasing evidence that echocardiographic sizing of the aortic annulus is accurate and is comparable to multidetector computed tomography (MDCT) sizing.5-8 This...
TAVR: Insights and Perspectives
Percutaneous valve intervention is a disruptive innovation that has transformed the landscape of interventional cardiology. Transcatheter aortic valve replacement (TAVR) is an established treatment option in inoperable, high-risk, and intermediate-risk patients that is strongly endorsed by both United States and European guidelines, with over 250,000 procedures that have now been performed worldwide.
The Equivalence of SAVR and TAVR
In just more than a decade since the first patients were enrolled in the PARTNER I trial, transcatheter aortic valve replacement (TAVR) has become the treatment of choice for elderly high-risk patients with severe aortic stenosis (AS) and those who are deemed unsuitable for conventional surgical aortic valve replacement (SAVR).
Cardiac Interventions Today - Innovations (March/April 2017)
The TrapLiner Catheter is a guide extension catheter with a trapping balloon in an all-in-one device. The straight, flexible extension provides deep-seating for extra backup support and coaxial alignment in challenging anatomies. The integrated balloon adds the ability to trap a guidewire during over-the-wire (OTW) catheter exchanges. This eliminates the extra step of deploying a percutaneous transluminal coronary angioplasty balloon to trap a guidewire when exchanging OTW microcatheters.
Aortic Valves: What’s Coming?
Over the past 10 years, transcatheter aortic valve replacement (TAVR) has become a transformative technology for the treatment of severe aortic stenosis (AS). The role of TAVR as an alternative to surgical aortic valve replacement (SAVR) is well accepted in some patient subsets and is under investigation in others.
Ask the Experts: What Is Your Institution’s Approach to CAD in TAVR Patients?
Determining the relative contribution of coronary artery disease (CAD) to symptoms in patients with severe aortic stenosis (AS) is challenging. Stress testing has poor diagnostic accuracy and is contraindicated in severe AS, and there are limited data on the use of fractional flow reserve in the setting of AS. All randomized clinical trials for transcatheter aortic valve replacement (TAVR) excluded patients with untreated, clinically significant CAD.
Making the Most of CT in TAVR Planning
For procedural planning of transcatheter aortic valve replacement (TAVR), CT has emerged as the standard of care.1-3 Unlike routine echocardiography, the acquisition of CT is operator independent and provides a full-body, three-dimensional (3D), and now four-dimensional (4D), assessment that may be analyzed remotely for procedural planning.
An Interview With Ralph Stephan von Bardeleben, MD
In Germany, the local heart team includes one heart surgeon, preferably involved or lucent to both surgical and interventional strategies, as well as an interventional cardiologist experienced in percutaneous valve interventions and surgical therapeutic strategies. The team is dynamically expanded to fellows of the valvular wards, imaging specialists, cardiovascular anesthesiologists, and heart failure specialists. Psychocardiologists, neurologists, and geriatricians are involved as needed.
Intra-Aortic Balloon Pump Counterpulsation: Old Friend or Foe?
Mechanical support in patients who present in the catheterization laboratory can serve several purposes but is generally related to three indications: high-risk percutaneous coronary intervention (PCI), acute myocardial infarction (AMI), and cardiogenic shock.
Current TAVR Devices
Since the first-in-human transcatheter aortic valve replacement (TAVR) performed by Cribier in 2002,1 this innovative procedure has had widespread recognition as the treatment of choice for severe aortic stenosis in inoperable patients2 and as a reasonable alternative to conventional surgical aortic valve replacement (SAVR) in patients with intermediate and high surgical risk.2-4 The first prototype transcatheter aortic valve (designed by Cribier and his start-up Percutaneous Valve...
Show More
loading
Actions
Is this you?
As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.Get in touch with Thomas
Contact Thomas, search articles and posts on X, monitor coverage, and track replies from one place.
Learn more about Muck Rack