Good morning! It’s just a quick site update. We didn’t have much going on with the sheet piling team at first—then suddenly, everything ramped up. Earlier, the platform was certified by the geotechnical engineer. That certification confirmed it could achieve 250 kPa bearing, and we confirmed that with nuclear density testing. We received results of: 95% on one test site 97% on the other The geotech report required results to be above 93%, so we met the threshold. Last week, we completed the testing.