Introduction Successful chromatographic separations critically depend on selecting the optimal combination of stationary and mobile phases to maximise resolution [1]. This process typically begins with the choice of a suitable stationary phase and column length, guided by factors such as column availability, manufacturer guidelines, solute physicochemical properties, analyst expertise, relevant literature, and anticipated solute-system interactions.
Is this you? As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.
Claim your profile
Articles by P. Jandera
Preparation and evaluation of versatile zwitterionic mixed-mode chromatographic stationary phases
High-performance liquid chromatography (HPLC) is a widely employed analytical technique in both scientific research and industrial applications. The chromatographic column is recognized as the core of the separation system, where the separation performance is significantly affected by the type, composition, structure, and surface properties of the packing material, and the most common packing materials are composed of fully porous spherical silica particles [1].
Purification of testosterone and its metabolites in urine using two-dimensional high-performance liquid chromatography for 13C/12C ratios analysis by gas chromatography/combustion/isotope ratio mass spectrometry
Anabolic steroids remain the most frequently detected prohibited substances in anti-doping programs. The detection of pseudoendogenous steroids like testosterone and its derivatives presents particular analytical challenges, as it requires sophisticated methods to distinguish between endogenous and exogenous sources of urinary testosterone.
Effect of stationary phase surface chemistry and particle architecture in proteomics
In the most widespread bottom-up proteomics analysis, the proteins are first digested into particular peptides, which are then separated and identified by liquid chromatography coupled to the mass spectrometry (LC-MS) [1]. This protocol is, without any doubt, the method of choice in current attempts to explore the functions of proteins in countless different samples and living systems [2].
Advanced applications of two-dimensional liquid chromatography in quantitative analysis of natural products
Over the past few decades, high performance liquid chromatography (HPLC) is widely recognized as a powerful and effective tool for the separation of chemical components in samples [1]. However, when analyzing complex samples, such as natural herbs, only limited compounds can be separated and determined by using the conventional HPLC systems even connecting to advanced and sensitive mass spectrometry (MS) due to the extremely low resolution of HPLC.
Separation of polyphenols by HILIC methods with diode array detection, charged aerosol detection and mass spectrometry: application to grapevine extracts rich in stilbenoids
Determining the phenolic composition of plant products is a major interest due to the bioactive roles of these compounds in plants and their health benefits for humans [1,2]. Polyphenols play a critical role in the adaptation of plants to their environment [3] and represent a potential alternative to conventional pesticides for plant protection [4].
Preparation and evaluation of a pyridine sulfonate betaine-based zwitterionic stationary phase for hydrophilic interaction chromatography
Since Alpert proposed hydrophilic interaction chromatography (HILIC) [1], HILIC chromatographic material have developed rapidly and the types of commercial and literature-reported stationary phases have become increasingly diverse [2,3]. Existing HILIC stationary phases mainly include bare silica and silica modified by polar groups like amines [4], diols [5], amides [6], glycans [7], ionic liquids [8], and zwitterions [9].
Peptide retention time prediction for hydrophilic interaction liquid chromatography at acidic pH in formic-acid based eluents
Hydrophilic interaction liquid chromatography (HILIC) is a separation method leveraging the interaction of hydrophilic analytes with an aqueous layer adsorbed onto a polar stationary phase [1,2]. This chromatographic mode was characterized in 1990 by Alpert, initially, demonstrating that cation-exchange and hydrophilic neutral materials can retain hydrophilic compounds at high organic solvent concentrations.
Chromatographic evaluation and application of nitrogenous heterocyclic ring-bonded stationary phase in hydrophilic interaction liquid chromatography
Reversed-phase liquid chromatography (RPLC) is the most universally used chromatography mode, which relies on the hydrophobic interaction to achieve the satisfactory separation of weakly polar and moderately polar compounds [1,2]. However, the weak or no retention effect and the limited polarity selectivity of RPLC on polar compounds hinder the successful separation [3].
A Comprehensive Study on Solvent Effect and Establishment of n-hexane solvent system based normal-phase liquid chromatography × reversed-phase liquid chromatography for Isolation of Natural Products - ScienceDirect
Two-dimensional liquid chromatography (2D-LC) offers superior separation capabilities compared to traditional one-dimensional liquid chromatography (1D-LC), making it an ideal optimal approach for the separation of complex mixture samples, particularly natural products. In all combinations of 2D-LC, the coupling of silica gel-based normal phase liquid chromatography (NPLC) and reversed-phase liquid chromatography (RPLC) is considered to possess the best separation orthogonality [1,2].
Advancing HIC method development: Retention-time modeling and tuning selectivity with ternary mobile-phase systems
Introduction Liquid chromatography (LC) method development (MD) frequently involves a trial-and-error based approach, wherein, various combinations of mobile phases, stationary phases, and operating conditions are assessed to find the optimal separation conditions [1]. This can be time consuming, resource intensive, and rely heavily on the expertise of the analyst. To address these challenges, retention modeling has become an increasingly valuable tool.
Analytical QbD for the optimization of a multimode HPLC method for the investigation of hydrochlorothiazide, diltiazem and propranolol release from 3D printed formulation
It is quite common for General Practitioners to treat patients with multiple treatment regimens for diseases such as hypertension, cholesterol and diabetes. It is also well-documented that the prescription of multiple drugs, leads to procedural complexity and reduces the adherence of the patients staking the efficacy of the clinical outcome [1].
Separation of Carbohydrates Using Dynamically Adsorbed Borate Stationary Phase for Hydrophilic Interaction Liquid Chromatography
Sugar and sugar alcohol are widely employed in the production of chemicals, pharmaceuticals, and food products [1], [2], [3]. These chemicals contain a high density of exposed hydroxyl groups, making them highly hydrophilic. Due to the structure complexity and strong polarity, the separation of sugars and sugar alcohols remains a challenge to this day.
Comprehensive analysis of the effective and intra-particle diffusion of weakly retained compounds in silica hydrophilic interaction liquid chromatography columns
Hydrophilic interaction liquid chromatography (HILIC) has become a powerful technique for the separation of polar and ionizable compounds in the context of samples of biological interest, particularly in the field of omics sciences (metabolomics, genomics, proteomics, glycomics…), but also in pharmaceutical, environmental, and food analysis [1], [2], [3], [4], [5], [6], [7], [8].
Show More
loading
Actions
Is this you?
As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.Get in touch with P.
Contact P., search articles and posts on X, monitor coverage, and track replies from one place.
Learn more about Muck Rack