This drill will reinforce the points of using a portable ground monitor as a first-strike weapon to initiate a defensive and/or an offensive attack, with the options to extend off the monitor with large or smaller-size handlines. A fast-attack monitor (FAM) is designed to be deployed quicky with minimal firefighters/staffing and deliver a high flow rate while being portable at the same time.
Is this you? As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.
Claim your profile
Articles by Mark van der Feyst
Effective Deck Gun Operations
Members of the Stockton (CA) Fire Department train on deck gun operations. Photo courtesy Stockton Firefighters Local 456. This training drill will reinforce the effectiveness of firefighters employing the deck gun as a first-strike weapon to dump half the on-board tank of water (at a minimum), while stretching a handline for interior attack. Some important points to reinforce for this drill are: The advantage of a straight tip is the distance of reach that can be achieved when flowing water.
Residential Fire Rescue: Tactically Primed and Ready!
Attention, Attention, Engine 1, Engine 3, Truck 1, Chief 1, respond to 32895 Monte Cristo Drive for reports of a structure fire in the residence. Called in by homeowner—multiple calls coming in on from others. Reports of people possibly trapped. When we hear these words being dispatched to us at the station or on the pager/phone system, we spring into action to start the response/rescue sequence.
4 challenges to fighting fire in the snow
As we face the winter deep freeze, we are reminded of how cold-weather operations can be strenuous. The firefighters operating in snow in the northern part of the country will certainly attest to this. The accompanying video shows exactly what it is like to have to work in the snow, which exacerbated the conditions the firefighters faced fighting this house fire. As much as we enjoy the snow for some recreational purposes, it does add strain to the firefighting operations. 1.
Fire Training: Maximizing the Hydrant
Photos by author After completing this lesson, the student will be able to explain and demonstrate the benefits of maximizing the hydrant when securing a pressurized water source. Firefighters will demonstrate maximizing a hydrant by securing it with two or three connections from available hydrant ports. Upon successful completion of this lesson, the student shall be able to: Describe the concept and purpose of double/triple-tapping a hydrant.
Back To Basics: The Rescue Sequence, Part 4
In the fourth part of our series on the rescue sequence, we are going into detail on ladder rescues. In part three we mentioned the option to use a ladder to rescue the occupant from a window after they have been dragged there by the search team. Dragging to the window is an excellent option for the search team – it may be the nearest exit point to head towards.
Back To Basics: The Rescue Sequence, Part 3
July 9, 2025 By Mark van der Feyst Features Digital training week In this edition, we are focusing on the third part of the rescue sequence, which is the actual rescue of the occupant. In Photo 1, you will see the word “rescue” in listed on the field note in a box. This was done to highlight the importance of this function and the amount of work that will need to be done to accomplish the task. Rescuing an occupant who is unable to self-rescue will be a fatiguing work cycle for the search crew.
Back To Basics: The Rescue Sequence, Part 2
Last month we started to examine the rescue sequence as it relates to residential structures and the occupants inside them. The sequence as starts with entry into the structure and then searching the areas within. The next step of the sequence is to locate the occupants. Focus on the floor The key fact to remember when trying to locate occupants within the structure is to focus your attention and efforts mainly on the floor.
Back To Basics: Multipurpose Garages Mean Multi Hazard Fires
Many homes across the country have a garage or multiple garages based upon the type of house they have and the size of land they possess. Some of these garages are attached to the house and some of them are detached. Apart from the house, a garage is a separate building unto itself. A garage is not just a big box with a roll up door. They are designed for certain purposes with different functions added in by the owner. A garage is a world of unknowns.
Back To Basics: The Rescue Sequence, Part 1
In our last edition, we looked at occupant drags with respect to removing the occupant from the residential structure once located by the search team. In our continued look at this topic, we are going to work backwards, in essence, with detailing the rescue sequence leading up to the removal of the occupant. In Photo 1, we have an outline showing what the rescue sequence looks like. This posted note was used for a hands-on class that was being taught in Nairobi, Kenya.
Back To Basics: Big Weapons For Offensive And Defensive Fire Fighting
Most engines and pumpers are equipped with a deck gun and/or a ground monitor for defensive operations. A defensive operation occurs when significant fire is present within a structure, making any interior operations impossible. In such cases, water is applied from the exterior in a defensive or distanced position. When taking a defensive position, large amounts of water must be discharged from the nozzles of a deck gun or ground monitor.
Video: Crews respond to structure fire on steep hillside
Not every structure fire occurs on level ground. While the majority of structure fire training occurs at facilities where the ground is level, providing access to all four sides of the structure, this is not always reflective of real-world conditions. In some response districts, residential structures are built on hillsides or amid mountainous terrain, such as in today’s corresponding video, in which a residential structure fire is underway on the side of a steep hill.
Video: Crews use deck gun to knock down residential fire
For most fire departments, the main function of the engine company is to deliver water – put water on the fire and the fire will go out. Most engine companies come equipped with a top-mounted deck gun, which can deliver a large volume of water from a great distance. The deck gun is one of the most valuable tools on the engine, but it’s often overlooked and underused by firefighters.
Protect eyes, ears from PPV fan
Most fire departments have a positive pressure fan on one of their fire apparatus. Used properly, these fans are extremely useful for ventilating a structure. When a fan is being set up for use at the doorway, there are some safety concerns. The first is hearing protection. The sound generated by the positive pressure fan is above acceptable levels allowed for a worker during a certain time frame. Hearing protection needs to be worn when operating these fans. The second is eye protection.
Wear hearing protection during truck checks
Firefighters are often subject to loud noises and we sometimes are unable to protect our hearing. There are certain situations where it is impossible for us to wear hearing protection — we just have to endure the loudness. But there are other times when we can wear hearing protection. One such occasion is when we are checking in our trucks. Although we may have the truck running outside, it still creates a loud noise that can damage our hearing.
Video: Crews respond to multi-boat fire at N.J. marina
Last month we looked at the potential hazards associated with aircraft fires. This month we’re moving to the water to discuss a recent incident at a New Jersey marina where multiple boats caught fire. Fighting a fire on a boat is completely different than battling a residential, commercial, industrial or mercantile fire. Unlike those calls, when a fire breaks out on a boat, there is no solid ground to work on. At a marina, floating docks called slips are used to secure the boats.
Engine Company Drafting Operations
When firefighters hear the term engine company operations, we often think of hoses and nozzles, advancing hoselines, and applying water to the fire. As exciting as that all sounds, and it is, there is more to engine company operations than just those items. One of the areas of this discipline is establishing water supply. This can be from a pressurized source such as a hydrant or from a static source such as a portable water tank or body of water.
Back to basics: Desensitizing firefighters – Red-light syndrome - Canadian Firefighter Magazine
In our last column for 2024, we are wrapping up our topic of desensitizing firefighters with a look at the red-light syndrome. This is where fire trucks drive right through red lights or stop signs as they respond to a call. When a 911 call comes in and the fire department is dispatched to respond, the personnel who are responding have the choice to act in a professional and structured manner, or adopt a freelance approach and cause issues as a result.
Primary Search: Focus on the Floor
Photos by author When responding to a residential structure fire, one of the essential firefighters must complete is a search of the structure. This will assist with the life safety fireground priority for the initial incident commander (IC) and subsequent ICs thereafter. The life safety priority must be considered for both firefighters on scene and for the occupants in the structure.
Video: Crews respond to an aircraft-involved structure fire
Responding to residential structure fires is the main business of the fire department – and the fire service does a very good job with these incidents. With a residential structure fire, the fuel load is dependent upon what is inside or around the structure. There are times when the fuel load will be enhanced by an unusual or introduced object, making the structure fire conflagrate at an increased rate.
Back to Basics: The rescue sequence, part 3 - Fire Fighting in Canada
September 6, 2024 By Mark van der Feyst This edition we are focusing on the third part of the rescue sequence which is the actual rescue of the occupant. In Photo 1, you will see the word “rescue” in listed on the field note in a box. This was done to highlight the importance of this function and the amount of work that will need to be done to accomplish the task. Rescuing an occupant who is unable to self-rescue will be a fatiguing work cycle for the search crew.
Being the Senior Firefighter
In the world of fire service training, many training sessions are conducted for officer leadership and management. The goal is to develop officers or future officers into good leaders and excellent managers and for these members to be more effective in their positions. Although this training is very worthwhile and value-added for the individual, there is a need to also consider those individuals who do not want to become officers and are content with just being a firefighter.
Video: How quint companies prioritize ground ladder operations
“Are you a truckie or an engine person?” This is a question often asked of firefighters regarding their preferred role on the fireground. Though a fun debate, there are many departments that do not have the luxury of dedicated truck companies or engine companies – they become quint companies, which are a combination of both.
Back to Basics: The rescue sequence, part 2 - Fire Fighting in Canada
Last month we started to examine the rescue sequence as it relates to residential structures and the occupants inside them. The sequence as starts with entry into the structure and then searching the areas within. The next step of the sequence is to locate the occupants. Focus on the floor. The key fact to remember when trying to locate occupants within the structure is to focus your attention and efforts mainly on the floor.
Not too big, not too small: Find the hoseline size that’s just right
Pulling off the right size hoseline is crucial in the success of a structure fire.
Firefighters and the Rescue: Being Too Safe?
Everything in the fire service is based on safety. Every day, firefighters train and operate in the hopes of greatly reducing the chance of personal injury or death from fires and various other emergencies. It’s their reason to be. The question arises: Are we being too safe, especially with respect to occupant rescue from residential structure fires and putting water on the fire?
Back to Basics: Hose Packs, Part 2 - Canadian Firefighter Magazine
Continuing our study into the different hose packs that we have available to us, this month we are looking at the New York load. As the name denotes, this load was developed by the Fire Department of New York (FDNY) and has been in service for many years as a staple in the FDNY’s tactical arsenal for hose deployment. As with the Denver Load, there will be three bundles of hose packaged to make up the load.
Back to Basics: Hose Packs, Part 1 - Canadian Firefighter Magazine
The first hose pack is the Denver Load. As the name alludes to, this hose load comes out of the Denver Fire Department – more specifically, from and by Assistant Chief Dave McGrail. It was he who designed and created the Denver Load based upon his experiences in dealing with standpipe/high-rise fires. Most hose loads that are configured using this load are going to be 2 ½”, or 65mm in diameter, which assists with making the load.
Back to basics: Desensitizing firefighters – Driving - Canadian Firefighter Magazine
In our continued series on desensitizing firefighters, we arrive at the topic of driving-related issues. Every fire department and every firefighter can relate to this category as they all have responding fire apparatus, and most firefighters are either driving the fire apparatus or are being driven in one. One of the main issues that the fire service finds themselves dealing with is the topic of speed. One aspect of speed is not driving to the conditions.
Back to Basics: Which flashlight is best? - Canadian Firefighter Magazine
The second type is pictured in photo 2. This type of light is a traditional right-angle flashlight. In the photo, the flashlight is positioned upside down to offer the firefighter a better advantage of being seen, to use the beam of light to aim low on the ground in front of the firefighter and reduce the position of where it sits on the front of the jacket for better comfort. The light does not have to be positioned like this and can be positioned upright if desired.
Back to Basics: Occupant drags - Canadian Firefighter Magazine
Occupants trapped inside a residence require our intervention to locate them and then remove them from the structure. The removal process needs to be quick and simple by utilizing exit points in the structure to our advantage. Using windows and exterior doors that are located nearest to the location of the occupant is going to be the best way to remove them. When we find a person, we tend to want to remove them using the same path that we took into the building.
More than ‘just a driver’: The expanding role of the driver/operator
With every call comes a fire apparatus, and with every apparatus comes a driver. Unfortunately, our drivers are often overlooked members on the scene. The reality is they do so much more than just drive the apparatus; they serve as an extremely valuable asset for the operation. In our current climate of limited fire service staffing, every set of hands is needed to fulfill the tasks that are required. The good news: The driver/operator can fill many voids: Assisting with ground ladder operations.
Back to Basics: The rescue sequence, part 1 - Fire Fighting in Canada
In our last edition, we looked at occupant drags with respect to removing the occupant from the residential structure once located by the search team. In our continued look at this topic, we are going to work backwards, in essence, with detailing the rescue sequence leading up to the removal of the occupant. In Photo 1, we have an outline showing what the rescue sequence looks like. This posted note was used for a hands-on class that was being taught in Nairobi, Kenya.
Video: Fireground conditions dictate aerial positioning
Utilizing an aerial truck at structure fires is valuable, as it provides tactical advantages for the incident commander. Though not every fire department has an aerial in their arsenal to deploy for structure fires, most can request one through mutual or automatic aid. Aerial advantages One of the tactical advantages of having an aerial on scene is the ability to flow water from an elevated height while the apparatus is staged back from the structure.
Keep hydrants clear of snow and obstructions
By Mark van der Feyst When people have hydrants in their lawn, they are inclined to decorate them or make them part of the garden. These decorations can be an obstruction that will hinder your access to the hydrant. The same can be said about wintertime for certain parts of the country. Snow can easily bury a hydrant making it difficult to locate and use. The same is true for tall grass around a hydrant.
Officer Development: How Shallow Is Your Depth Chart?
Staffing is a common issue many fire departments face today. Not only is the fire service dealing with a staffing shortage in terms of having the required or desired number of firefighters on duty or responding to calls, but more so with finding people who even want to be a firefighter. With this problematic shortage also comes the issue of backfilling the ranks with qualified people to move up into officer roles, as many firefighters are retiring.
Video: Speed matters when applying water to flames
When responding to structure fires, the faster crews can apply water to flames, the better the outcome for everyone on scene. However, the method or operation by which water is applied varies based on the situation at hand, the number of firefighters and resources available, and the size and location of the fire. In today’s training video, you can see the immediate impact of water being applied to a fire. The building on fire has significant flames showing from the rear on both sides.
Back to Basics: Desensitizing firefighters – Communication - Canadian Firefighter Magazine
As we continue to look at how firefighters become de-sensitized, we are going to deal with the topic of communications on the fire ground. This is one main area that always requires constant attention and improvement from all involved. With every LODD Report, one consistent recommendation is regarding communications. Let’s look at some common issues that are consistently present on the fire ground. Active listening is a skill that needs to be exercised when using any type or brand of portable radio.
Back to Basics: Which flashlight is best?
March 22, 2024 By Mark van der Feyst Which flashlight is the best one to carry and use? This is the question that many firefighters ask and have varying opinions about – some good opinions and some not-so-good. Regardless of where you stand and which one you want to use, every firefighter needs to carry at least one flashlight, if not two of them. That is my opinion, and I will explain why and which ones I recommend. The first type of flashlight that is available is pictured in photo 1.
Video: Crews respond to a multi-structure rowhouse fire
In many urban and suburban neighborhoods, developers maximize land use by building residential structures very close together. While single-family homes may be tight on space in between dwellings, one rowhouse block of units will contain multiple dwellings side by side to form one large building – a challenge for firefighters. This month’s video showcases that challenge as crews respond to row housing with three units showing full fire involvement from the rear.
The Tactical Firefighter
The moniker “tactical firefighter” is not just reserved for one specific area of the fire service—it is applied and is applicable to all aspects of our operations on the fireground and in the station. The station is where we prepare ourselves for the operations side of the business by prepping equipment, trucks, gear, attitudes, approaches to certain situations, tactical objectives, training, and so forth.
Video: Listen to the smoke - Why flames are only one piece of the fire puzzle
Every structure fire emits smoke, as it is a constant byproduct of combustion. And, regardless of the size or location of the fire, the smoke will find an opening and exit the building due to the pressure differentiation, as smoke always seeks out the low-pressure zone outside the structure. This fact should be considered by crews on scene, as the smoke provides important information that can assist firefighters in determining how best to attack the blaze.
Back to Basics: Hose packs part 3
For the last two issues in 2023, we began looking at the three different hose loads that are commonly used for any standpipe operations – giving them the name of high-rise or standpipe hose packs. If you recall back to our first article, we detailed the reason for calling them hose packs instead and listed the three types that are available. We have come to the third part of our series with a look at the Chicago load.
Fire Apparatus Basics: Cold Weather Truck Checks
Photos by author As we start a new year in the fire service, firefighters find themselves in the middle of winter, which requires us to be diligent to ensure our equipment is in good working order. In cold weather operations, it is imperative to make sure our trucks are running properly and safely. It is our job to check our fire apparatus on a routine basis. This may be on a weekly, bi-weekly, monthly schedule—or daily.
Video: Water-to-nozzle delays hamper fireground operations
We all know that water puts out fire and that getting water quicky on the fire will make the situation better for everybody. When we break down this basic knowledge into action steps on the fireground, we can do this more effectively. There are three parts to this process: Step 1: Getting water from the source to the pump; Step 2: Getting water from the truck/pump to the nozzle; and Step 3: Getting water from the nozzle to the fire.
Firefighter injury prevention is about working smarter
The most common injuries to firefighters both on the fireground and in training involve sprained joints and muscles and ligaments that are strained or over exerted. There have been many campaigns to educate and train firefighters to be aware of their work habits and to work smarter rather than harder. There is much merit and truth to “work smarter, not harder” when it comes to our line of work and service.
Garbage bin fires: Prepare for the worst, hope for the best
The waste management industry is a large and multi-faceted entity with a presence everywhere. At all building types, there will be some form of refuse collection and disposal service system. Particularly at non-residential buildings, firefighters may be called to respond to a garbage bin on fire. Garbage bin fires can be misleading and at times may expand into larger fires within the nearest structure.
Video: Limited-access building poses threat to fire crews
Securing our homes, places of business and private facilities is critical to our safety. But some commercial, industrial or mercantile-style buildings have significant fortification to detract potential intruders. Any structure of this type will pose a danger when responding to a fire due to the nature of the building, the construction methods and materials, and the contents inside. In today’s video, crews respond to a fire in one of these types of buildings with limited access.
Back to Basics: Hose Packs, Part 2
November 22, 2023 By Mark van der Feyst Continuing our study into the different hose packs that we have available to us, this month we are looking at the New York load. As the name denotes, this load was developed by the Fire Department of New York (FDNY) and has been in service for many years as a staple in the FDNY’s tactical arsenal for hose deployment. As with the Denver Load, there will be three bundles of hose packaged to make up the load.
Back to Basics: Hose Packs, Part 1
On our fire trucks, we will have different configurations for our hose lines with some being pre-connected or others being a dead lay with the expectation of hooking up to a discharge when advancing. There are times when there will be hose arranged in a kit or load to be used for high-rise operations. Most fire departments will not have high-rises to respond to, so they opt out of having these kinds of kits or loads on their trucks, but they will have buildings that contain standpipe systems.
Show More
loading
Actions
Is this you?
As a journalist, you can create a free Muck Rack account to customize your profile, list your contact preferences, and upload a portfolio of your best work.Get in touch with Mark
Contact Mark, search articles and posts on X, monitor coverage, and track replies from one place.
Learn more about Muck Rack